Disk Health & SMART¶
Lumiverse can read SMART health information from physical HDDs, SATA SSDs, and NVMe SSDs. Open Settings → Operator → Disk Health to see the latest result.
SMART is a useful early-warning system, not a guarantee that a drive will or will not fail. Keep tested backups regardless of the reported state.
Install smartmontools¶
From the Lumiverse project directory, run:
bun run install:smartctl
The command detects the supported package manager on your system and installs the smartmontools package, which provides smartctl. On Linux it opens the normal sudo prompt only for the package-manager command; Lumiverse never receives or stores your administrator password.
After it succeeds, restart Lumiverse and use Refresh SMART Data in Settings → Operator → Disk Health.
Automatic first-run setup
The first-run wizard offers this installation automatically. Run bun run install:smartctl later if you skipped it or if the installation did not complete.
If the installer cannot install it¶
Install smartmontools with your operating system's package manager, then restart Lumiverse.
| Platform | Command |
|---|---|
| Debian / Ubuntu | sudo apt-get install smartmontools |
| Fedora / RHEL | sudo dnf install smartmontools |
| Arch Linux | sudo pacman -S smartmontools |
| Alpine | sudo apk add smartmontools |
| openSUSE | sudo zypper install smartmontools |
| macOS (Homebrew) | brew install smartmontools |
On Windows, install smartmontools with its installer or choco install smartmontools -y, then restart Lumiverse as an Administrator. Native Termux normally cannot access physical disks, so Disk Health is unavailable there by default.
Linux: running Lumiverse with SMART access¶
On Linux, reading a physical drive's SMART log normally requires root-level access to the block device. Installing smartmontools is not enough by itself: the Lumiverse backend process must currently run with sudo/root privileges to collect SMART data.
- Stop the normal Lumiverse process.
- Install smartmontools with
bun run install:smartctl. -
From the project directory, start Lumiverse with:
sudo -E ./start.sh -
Open Settings → Operator → Disk Health and select Refresh SMART Data.
-E preserves the current shell environment so the elevated launcher can find a Bun installation that belongs to your user account. If your system does not permit sudo -E, start it with explicit environment values instead:
sudo env "PATH=$PATH" "BUN_INSTALL=${BUN_INSTALL:-$HOME/.bun}" ./start.sh
Running the whole server as root
This grants root access to Lumiverse, its installed extensions, and every process it starts. Use it only on a trusted, locally administered machine. Keep remote access disabled unless it is protected by strong authentication and a trusted network. Do not make block devices world-readable or add the service user to a broad disk-access group just to enable SMART; those changes can also permit raw disk writes.
File ownership
A root-run server can create root-owned files in data/, logs, and caches. If you later return to running Lumiverse as your normal user, fix the ownership first:
sudo chown -R "$USER":"$(id -gn)" data
Services and Docker¶
For a system service, configure the Lumiverse process to run as root and use absolute paths for the working directory and Bun executable. Do not rely on an interactive sudo prompt in a service definition.
Docker needs a different form of access: map only the specific host devices to monitor and grant the required raw-I/O capability. See the commented SMART example in docker-compose.yml. Do not use Docker's privileged: true mode solely for Disk Health.
Understanding the health status¶
| Status | Meaning | What to do |
|---|---|---|
| Healthy | No SMART failure or warning evidence was reported. | Continue normal backups and periodic checks. |
| Warning | SMART has a historical pre-fail condition, logged errors, or a concerning SSD metric. | Back up important data promptly and inspect the condition text. Watch whether the count changes. |
| Failing | SMART says the drive is failing, a pre-fail value is below its threshold now, or NVMe reports a severe condition such as read-only mode. | Back up immediately and plan to replace the drive. |
| Unavailable | Lumiverse could not read SMART data. This is not a health result. | Check installation, Linux privilege, USB/SATA bridge support, or Docker device access. |
| Standby | Lumiverse deliberately skipped a sleeping drive. | Refresh after the drive is active if you need a result; Lumiverse will not wake it just for monitoring. |
When SMART finds a warning or failure, owners and admins receive a Disk Health toast once per browser page load. It names the affected drive and the evidence behind the alert. The current alert is re-delivered periodically for operators who connect after startup.
SSD metrics¶
Lumiverse shows only values that the SSD controller actually reports. ATA/SATA attribute names are vendor-specific, so some fields may be absent.
| Metric | Meaning |
|---|---|
| Wear used / Endurance remaining | The controller's estimate of rated write endurance used and left. NVMe may report more than 100% used after its rated endurance is exhausted. |
| Available spare | Remaining replacement flash blocks on NVMe. A value at or below the drive's threshold is a warning. |
| Data written | Host writes reported by the controller. This is useful for comparing with the drive's endurance rating, but it is not a direct failure prediction. |
| Media errors | NVMe media/data-integrity errors, or the closest ATA equivalent when available. Non-zero values deserve investigation. |
| Program / erase failures | NAND programming or erase failures reported by some SATA SSDs. Non-zero values are warnings. |
| Wear-leveling / reserved blocks | Vendor-specific counters for flash wear and spare-block consumption. Compare their trend over time rather than assuming a universal threshold. |
| Unsafe shutdowns | NVMe power losses without a clean shutdown. This is useful context, but does not by itself mean the SSD is failing. |
HDD metrics¶
In addition to temperature and error counters, rotating drives show these lifecycle values when supported:
| Metric | Meaning |
|---|---|
| Power-on hours | Total time the drive has been powered. Useful context for age and warranty, not a failure verdict by itself. |
| Power cycles | Number of times the drive has been powered on. |
| Start/stop cycles | Number of spindle start/stop operations. |
| Load/unload cycles | Number of head-load or head-park cycles. Frequent parking can make this rise quickly on some laptop drives. |
| Reallocated sectors | Sectors remapped to spare space. A rising count is a reason to back up and investigate. |
| Pending sectors | Sectors waiting to be re-tested or remapped. Back up promptly; these are often more urgent than a stable historical reallocation count. |
| Uncorrectable sectors | Sectors the drive could not read during an offline scan. Treat a non-zero or rising value seriously. |
Pre-fail conditions¶
Pre-fail is an ATA SMART attribute category, not an immediate failure message. A pre-fail attribute matters when its WHEN_FAILED state reports one of the following:
- FAILING_NOW — the attribute's normalized value is currently at or below its manufacturer threshold. Lumiverse marks the drive as Failing.
- In_the_past — the attribute crossed its threshold previously. Lumiverse marks it as a Warning and includes the attribute name in the toast and Disk Health details.
For example, Cumulativ_Corrected_ECC with In_the_past means the drive recorded that pre-fail condition in its history. It does not prove the drive is failing right now, but it is a good reason to verify backups, inspect the full smartctl --all /dev/sdX report, and monitor for new or increasing errors.
Troubleshooting¶
smartctl could not read SMART data from this device¶
On Linux, first confirm that Lumiverse itself was started with sudo as described above. Then test the drive directly in a local terminal:
sudo smartctl --all /dev/sda
Replace /dev/sda with the device shown in Disk Health. If the command works directly but not in Lumiverse, restart the elevated Lumiverse process and refresh the page. USB-to-SATA bridges sometimes need a transport-specific smartctl device type; Lumiverse attempts auto-detection, but not every bridge exposes SMART data.
No drives found in Docker¶